BXSMD - M27-HEAVY DUTY CHROME & METAL POLISH

  • MSDS: BXSMD
  • Manufacturer: MEGUIAR'S INC
  • Product Name: M27-HEAVY DUTY CHROME & METAL POLISH
  • National Stock Number: 7930-00N026894
Product Identification

Product ID:M27-HEAVY DUTY CHROME & METAL POLISH
MSDS Date:04/28/1993
FSC:7930
NIIN:00N026894
MSDS Number: BXSMD

Responsible Party
MEGUIAR'S INC
17991 MITCHELL SOUTH
IRVINE, CA 92714
US

Emergency Phone: 800-854-8073

Info Phone: 714-752-8000

Cage: EO362

Contractor
MEGUIARS INC/FORMERLY MIRROR BRIGHT POLISH
17177 IRVINE, CA 92714 US

Telephone: 714-752-8000

Cage: 14088

Ingredients

SILICA, AMORPHOUS, DIATOMACEOUS EARTH; (NATURAL

CAS: 61790-53-2

RTECS: HL8600000

Fraction By Weight: 3-8%

OSHA PEL 20 MPPCF; Z-3

ACGIH TLV: 10 MG/M3 TDUST


PETROLEUM DISTILLATE; (LIGHT DISTILLATE)

CAS: 64742-14-9

Fraction By Weight: 3-8%

OSHA PEL N/K

ACGIH TLV: N/K


SILICA, CRYSTALLINE - TRIPOLI; (TRIPOLI)

CAS: 1317-95-9

RTECS: VV7336000

Fraction By Weight: 10-20%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST


MINERAL SPIRITS; (HYDROTREATED HEAVY NAPHTHA)

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: 2-5%

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIA (SOLUTION) (SARA 302/313) (CERCLA)

CAS: 7664-41-7

RTECS: BO0875000

Fraction By Weight: 0.5-2%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM/35 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


8% MAX

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:PROLONGED OR INTENTIONAL
EXPOSURE TO HIGH CONCENTRATIONS MAY CAUSE SLIGHT IRRITATION TO
SKIN, AND BREATHING TRACTS.
Explanation of Carcinogenicity:CRYSTALLINE SILICA-TRIPOLI: IARC GROUP
2A, SUP 7, P 341, 1987; ANTICIPATED CARCIN, NTP 7TH ANN REPORT ON
CARCINS, 1994.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . SKIN:WASH WITH SOAP AND WATER. EYES:FLUSH WITH CLEAR WATER
FOR @ LEAST 15 MINUTES. INGEST:DO NOT INDUCE VOMITING.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:DRY CHEMICAL, WATER, FOAM, CO*2.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:CONTAIN AND ABSORB IN METAL, PLASTIC OR GLASS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM ACIDS AND OXIDIZERS.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST:ADEQUATE.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>380F,>193C
Melt/Freeze Pt:M.P/F.P Text:>380F,>193C
Vapor Pres:<10
Vapor Density:>1
Spec Gravity:1.00
pH:8.0
Evaporation Rate & Reference:<1
Solubility in Water:APPRECIABLE
Appearance and Odor:LIGHT BROWN LIQUID WITH SLIGHT AMMONIA ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS AND ACIDS.
Stability Condition to Avoid:AVOID EXTREME HEAT CONDITIONS.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:SANITARY LANDFILLS FOR ABSORBENT MATERIALS, OR
AS REQUIRED BY FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.